Closed system

SISTEMACERRADO
 

Bionector

Closed System, needleless, self-sealing, for intravenous processes. Product designed for patient and user protection during catheter handling.

Bioconector

Code: 896.03

Sterile Disposable Connector, green with white Bionector type. Linear lipid resistant flow with neutral pressure of multi-purpose self-sealing, length 23.90 mm, for medicine infusions, sampling and injection of fluids, without needle to avoid punctures, with a Luer-Lock connection and another anti-pollution spring that cancels unused spaces, inner diameter 16 G, of medical grade stainless steel, dead volume 0.02ml, flow 170 ml/mm.

Compatible luer Dead volume ml Flow ml/min Number of connections Resistance against pressure
Usable with all male Luer devices with inner diameter equal to or greater than 1.40 mm 0.02 170 300 760 (1 bar)
Compatible luer Usable with all male Luer devices with inner diameter equal to or greater than 1.40 mm
Dead volume ml 0.02
Flow ml/min 170
Number of connections 300
Resistance against pressure 760 (1 bar)

Vadspike B


Vadspike B

Code: 856.015

Vadsite needle-free connector, with bayonet for the injection and extraction of liquids from IV vial or bag, with bidirectional flow, Luer Lock connection, without air filter, lipid resistant, RX compatible, latex free. Flow rate 182 ml/min.

Octopus 1-way short catheter

REDUCE RISKS OF MECHANICAL IRRITATION BY MANIPULATION

Octopus de 1 vía para catéter corto

Code: 5222.014

1-way polyurethane catheter extension, extra-flexible and of very low dead volume. 1-way: Inner diameter 1.5 mm, external diameter 2.50 mm, length 10 cm, dead volume 0.29 ml, Bionector, with safety clamp

Code Way Inner mm External mm Length cm Dead volume ml
5222.014 1 1.5mm 2.50mm 10cm 0.29ml
Code 5222.014
Way 1
Inner mm 1.5mm
External mm 2.50mm
Length cm 10cm
Dead volume ml 0.29ml

OCTOPUS DE 1 VÍA PARA CATÉTER CORTO

PARA REDUCIR RIESGOS DE IRRITACIÓN MECÁNICA POR MANIPULACIÓN

 

Octopus 1 vía para catéter corto

Code: 5222.014

1-way polyurethane catheter extension, extra-flexible and of very low dead volume. 1-way: Inner diameter 1.5 mm, external diameter 2.50 mm, length 10 cm, dead volume 0.29 ml, Bionector, with safety clamp


Code Way Inner mm External mm Long cm Dead volume ml
5222.014 1 1.5mm 2.5mm 10cm 0.29ml
Code 5222.014
Way 1
Inner mm 1.5mm
External mm 2.5mm
Long cm 10cm
Dead volume ml 0.29ml

OCTOPUS FOR INTENSIVE THERAPY WITH SPECIFIC LUMEN

FOR VENOUS PRESSURE OR BLOOD SAMPLE

Codes: 841.264 – 842.209

2-way polyurethane catheter extension, extra-flexible and very low dead volume. 1-way and 2-way: Inner diameter 1.5 mm, external diameter 2.5 mm, Length 3 cm, dead volume 0.30 ml, with two non-return valves and two bionectors, with safety clamps.
Codes Ways Ways with anti-reflux valve Inner mm External mm Length cm Dead volume ml
841.264 2 0 1.5 mm 2.50 mm 10 cm 0.34 ml
842.209 2 1 1.5 mm 2.5 mm 6 cm 0.34 ml – 0.36 ml
Ways with anti-reflux valve Ways without anti-reflux valve

OCTOPUS FOR INTENSIVE THERAPY WITH SPECIFIC LUMEN

FOR VENOUS PRESSURE OR BLOOD SAMPLE.

Code: 841.364

Polyurethane catheter extension, extra-flexible, transparent and of very low dead volume. 3-way: Inner diameter 1.5 mm, external diameter 2.50 mm, length 10.6 cm, with bionector in each way and safety clamps.

Codes Way Ways with anti-reflux valve Inner mm External mm Length cm Dead volume ml
841.364 3 0 1.5 mm 2.5 mm 10 cm 0.34 ml
Ways without anti-reflux valve

OCTOPUS FOR INTENSIVE THERAPY WITH SPECIFIC LUMEN

FOR VENOUS PRESSURE OR BLOOD SAMPLE.

Code: 842.414

Polyurethane catheter extension, extra-flexible, transparent and very low dead volume. 4-way: Inner diameter 1.5 mm, external diameter 2.50 mm, length 6 cm, with bionector in each way and safety clamps.

Codes Way Ways with anti-reflux valve Inner mm External mm Length cm Dead volume ml
842.414 4 3 1.5 mm 2.5 mm 6 cm 0.36 ml 0.25 ml
Ways with anti-reflux valve
Ways without anti-reflux valve
 

OCTOPUS FOR INTENSIVE THERAPY WITH SPECIFIC LUMEN

FOR VENOUS PRESSURE OR BLOOD SAMPLE.

Code: 842.514

Polyurethane catheter extension, extra-flexible, transparent and very low dead volume. 5-way: Inner diameter 1.5 mm, external diameter 2.50 mm, length 6 cm, with bionector in each way and safety clamps.

Codes Way Ways with anti-reflux valve Inner mm External mm Length cm Dead volume ml
842.514 5 4 1.5 mm 2.5 mm 6 cm 0.36 ml 0.25 ml
Ways with anti-reflux valve
Ways without anti-reflux valve

OCTOPUS WITH NON-RETURN VALVE TO PREVENT THE RISK

OF RETURNS DURING INJECTION OR INFUSIONS

Code: 841.232

2-way polyurethane catheter extension, extra-flexible and very low dead volume. 1-way and 2-way: Inner diameter 1.5 mm, external diameter 2.5 mm, Length 3 cm, dead volume 0.30 ml, with two non-return valves and two bionectors, with safety clamps.

Codes Way Ways with anti-reflux valve Inner mm External mm Length cm Dead volume ml
841.232 2 2 1.5 mm 2.5 mm 3 cm 0.30 ml
Way with anti-reflux valve

OCTOPUS WITH NON-RETURN VALVE TO PREVENT THE RISK

OF RETURNS DURING INJECTION OR INFUSIONS

Code: 842.232

3-way polyurethane catheter extension, extra-flexible and very low dead volume. 1,2,3-way: Inner diameter 1.5 mm, external diameter 2.50 mm, Length 6 cm, dead volume 0.44 ml, with 3 non-return valves and 3 Bionector, with safety clamps.

Codes Way Ways with anti-reflux valve Inner mm External mm Length cm Dead volume ml
842.232 3 3 1.5 mm 2.5 mm 6 cm 0.30 ml
Way with anti-reflux valve