Oncology

Oncologia

Micro-Sitimplant titanium implantable port

Cámara implantable de titatio micro-sitimplant

Code:
2211.67 – 2211.77

Very low-profile implantable titanium port, silicone intravenous catheter, entirely radiopaque XRO, 80 cm long, and anti-kinking sleeve, centimeter marking along the entire length of the catheter, detachable catheter, compatible with MRI imaging, catheter guide, adapter for purging detachable catheters, Huber bevel needle, 22G x 20 ml Hubsite needle, polyurethane perfusion extension, 1 desilet with peelable band, 1 10 ml syringe, 1 tunneling needle.

ReferenceSilicone catheter XRO
 Ø 1.1 x 2.2 mm Fr 6.6Ø 0.8 x 1.3 mm Fr 4RemovableKit with peelable DesiletNitinol Guid
2211.67X XXX
2211.77XXXX 

Reference 2211.67
Silicone catheter XROØ 1.1 x 2.2 mm Fr 6.6X
Ø 0.8 x 1.3 mm Fr 4 
RemovableX
Kit with peelable DesiletX
 Nitinol GuidX
Reference 2211.77
Silicone catheter XROØ 1.1 x 2.2 mm Fr 6.6 
Ø 0.8 x 1.3 mm Fr 4X
RemovableX
Kit with peelable DesiletX
 Nitinol Guid 

 

Implantable Port with Detachable Venous Catheter and peelable Desilet Introducer

 

Cámara implantable con catéter venoso separable e introductor desilet peleable

Code:
2201.33

Implantable port with silicone-coated titanium reservoir, bio-compatible, with removable intravenous catheter entirely XRO of 60 cm in length and anti-kinking sleeve, centimeter marking along the entire length of the catheter, 1 tunneling needle, 1 inject site, 1 vein pick.

ReferenceSilicone catheter XRO
 FrHeight 13.5 mmWeight 11gDead volume 0.51mlPuncture area 1.3 cmNitinol GuideDesilet introducercm
6.6XXXXXXPeelable

Reference 6.6
Silicone catheter XROFrX
Height 13.5 mmX
Weight 11gX
Dead Volume 0.51mlX
Puncture area 1.3 cmX
Nitinol GuideX
Desilet introducercmPeelable

PPS® CT

“POWER INJECTABLE SAFETY HUBER NEEDLES”

PPS CT

The PPS® CT is a curved safety huber needle supplied with connection tubing ideal for accessing power-injectable ports. This device can be used for power injection of contrast media (up to 300 psi / 2.07 MPa maximum) during CT scan (computerized tomography) or MRI (magnetic resonance imaging) exams, and is MR

  • Prevention of needlestick injuries
  • Allowing positive pressure
  • MRI conditional and CT scan compatible
  • No risk of contact with the body of the needle
  • Protection up to discarding in sharps container
  • in different lengths and diameters
  • with or without Y-site
Its is supplied with:
  • Luer-Lock connectors, are provided, on which closed protective caps are screwed (end of the main line and of the Y site) which must not be used as sealing caps.
  • and a clamp (2 clamps for references including an Y-site) that indicates the maximum flow rate of the PPS CT.
Gauge Needle Ø (mm) Needle Length (mm) Without Y site With Y site
███ 22 G 0.7 17 801707
███ 22 G 0.7 20 802007 812007
███ 22 G 0.7 25 802507 812507
███ 22 G 0.7 30 803007
███ 22 G 0.7 35 803507
███ 20 G 0.9 17 801709
███ 20 G 0.9 20 802009 812009
███ 20 G 0.9 25 802509 812509
███ 20 G 0.9 30 803009
███ 20 G 0.9 35 803509
███ 19 G 1.1 17 801711
███ 19 G 1.1 20 802011 812011
███ 19 G 1.1 25 802511 812511
███ 19 G 1.1 30 801711
███ 19 G 1.1 35 803511
*The PPS CT is not composed of natural latex (raw-materials and packaging) with DEHP-free tubing.

PPS® FLOW+

“AUTOMATIC POSITIVE PRESSURE SAFETY HUBER NEEDLES WITH”

PPS 3flow

Thanks to its specific design and one-hand extraction, PPS Flow + allows automatic positive pressure helping to reduce catheter occlusion. Catheter occlusion is the most common complication in long-term port use implantable (up to 21.5% of catheters may be occluded). Allows easy application of positive pressure during needle withdrawal, reducing thus the incidence of return.

PPS 2flow

Manual Positive Pressure: Blood reflux still in 17% of cases (operator-dependent) Automatic Positive pressure: Blood reflux only in 7% of cases

PPS 4flow

Prevention of needlestick injuryPPS retrait
  • No rebound effect at the withdrawal of the needleNo rebound effect at the withdrawal of the needle
  • No risk of contact with the body and the tip of the needle
  • Total protection up to discarding in sharps container
Visibility of puncture site
  • Access site provides excellent visibility of inflammation or exudation.
Cost reduction
  • Reduction of the use of fibrinolytic agents
  • Reduction of cost following catheter obstruction complications (X-Rays, nurse time, explantation, etc.)

Ergonomic Design

PPS flow

Gauge Needle Ø (mm) Needle Length (mm) Without Y site With Y site
███ 22 G 0.7 15 701507*
███ 22 G 0.7 17 701707
███ 22 G 0.7 20 702007 712007
███ 22 G 0.7 25 702507 712507
███ 22 G 0.7 30 703007
███ 22 G 0.7 35 703507
███ 20 G 0.9 15 701509*
███ 20 G 0.9 17 701709
███ 20 G 0.9 20 702009 712009
███ 20 G 0.9 25 702509 712509
███ 20 G 0.9 30 703009
███ 20 G 0.9 35 703509
███ 19 G 1.1 17 701711
███ 19 G 1.1 20 702011 712011
███ 19 G 1.1 25 702511 712511
███ 19 G 1.1 30 703011
███ 19 G 1.1 35 703511