Neonatal line
Premistar: Rifampicin-miconazole–impregnated catheter
“Reduce días de estancia, se coloca premistar en los pacientes neonatales”
Code:
6261.20
Description: 1 FR Polyurethane catheter impregnated with rifampin and miconazole (inner diameter 0.17 mm, external diameter 0.35 mm), length 20 cm, for peripheral neonatal and pediatric insertion for parenteral nutrition and drugs administration.
With fixation wings and extensions of 8 cm, equipped with clamp. Peelable metal introducer needle, length 19mm, 24 GA (external diameter 0.7 mm). Soft tip to verify safe extraction.
Code | Catheter | Introducer | |||||||
Length cm | Ext. Ømm | Fr | Flow rate (1 bar of pressure) ml/min | Prim. vol. ml | Type | Length mm | Ext. Ømm | GG | |
6261.20 | 20 | 0.35 | 1 | 0.7 | 0.09 | Detachable needle | 19 | 0.7 | 24 |
Code | 6261.2 | |
Catheter | Length cm | 20 |
Ext. Ømm | 0.35 | |
Fr | 1 | |
Flow rate (1 bar of pressure) ml/min | 0.7 | |
Prim. vol. ml | 0.09 | |
Introducer | Type | Detachable needle |
Length mm | 19 | |
Ext. Ømm | 0.7 | |
GA | 24 |
Premicath 1 Fr
Code: 1261.20
Radiopaque peripheral vascular access catheter, 1Fr Gauge (0.17 inner diameter, 0.36 external diameter), length 20 cm, centimeter marking and double marking every 5 cm, in thermosensitive, with 8 cm polyurethane extension and fixing wings, peelable metal introducer needle, length 18 mm, 24 Ga (0.7 mm external diameter), the extensions are equipped with clamp. Black tip to verify safe extraction. With two needle-free Bionectors, length 23.90mm with a 0.02ml dead volume, flow 170 ml/min.
Code | ØInt. – ØExt. mm | Long.cm | Gauge (G) | French | Dead volume ml | Flow (ml/min) at 1 bar/14.5 psi |
1261.20 | 0.17 – 0.35 | 20 | 28 | 1 | 0.09 | 0.7 |
Code | 1261.20 |
ØInt. – ØExt. mm | 0.17 – 0.35 |
Long.cm | 20 |
Gauge (G) | 28 |
French | 1 |
Dead volume ml | 0.09 |
Flow (ml/min) at 1 bar/14.5 psi | 0.7 |
Epicutaneo-Cava Catheter
Neocath 24 / 2 Fr
Code: 2184.00
BASIC CHART: 060.165.0815
2 FR silicone catheter for percutaneous access, 30 cm long, markings every centimeter, 20 cm extension, Easy-Lock blue connector and 19 G metal introducer needle, 27 mm long, facilitating catheter sliding, measuring tape included, the extension is equipped with a clamp.
Nutriline Catheter
Code: 1252.35
2 FR Polyurethane Catheter (0.3 mm internal diameter, 0.6 external diameter), length 30 cm, for neonatal and pediatric peripheral insertion for parenteral nutrition and drug administration. Centimeter marking and black mark on the distal end to verify safe extraction. With fixation wings and 10 cm polyurethane extension, equipped with clamp, 21 mm long microflash introducer, 20 GA, measuring tape included.
Nutriline catheter
“Evitar las punciones múltiples gracias a la doble luz”
Code:
1252.235
Double Lumen
Allows simultaneous administration of incompatible solutions
Preserves the venous capital of the newborn.
Avoid trauma related to repeated punctures.
Central venous catheter, Two-way Nutriline Twinflo, 2FR, length 300 mm, 24 G, bio-stable PUR, thermosensitive. Dead volume 2 x 0.2 ml flow 1.45 ml/min x two-way. With Microflash short peelable introducer, 20 G, and measuring tape included. The extensions are equipped with clamp, two-way identified with green luer and the other identified with orange luer, with three needle-free bionectors, length 23.90 mm, with a 0.02 ml dead volume, 170 ml/min flow. With fixation system for self-adhesive catheter, hypoallergenic, with integrated Velcro. Black tip to verify safe extraction. Centimeter marking and double marking every 5 cm.
Multicaths
2-Way Codes:
(1203.123 -12.5 cm)
(1202.063 – 6 cm)
Double-Lumen 4.5 FR catheter made of radiopaque BIOSTABLE thermosensitive polyurethane with soft fixation wings and two lumen identified by “Proximal” and “Distal” for perfusions, internal lumen of the proximal line 20 G, distal line 20 G, with introducer needle 21 G length 40 mm and 5 ml syringe, a straight metal guide length 40 cm and diameter 0.46mm with a dilator.
Code:
157.064 – 157.114
Central Venous Catheter inserted by Seldinger Technique, double lumen 3 FR, intravenous polyurethane thermo sensitive and radiopaque with soft fixation wings and two extensions marked as “Proximal” and “Distal” for infusions, needle or short catheter to perform the puncture, puncture needle, straight metal guidewire, a dilator, a membrane cap, a 5 ml syringe, a scalpel, Proximal 22G, NITINOL straight guidewire length 50 cm, diameter 0.30mm with a dilator.
Code | Catheter (PUR) | Flowrate ml/min | Dead volume ml | Straight guide | ||||
Long.cm | Distal | Proximal | Distal | Proximal | I-0.9.cm | ØMM | ||
157.064 | 6 | 4,4 | 4,4 | 0,09 | 0,09 | 50 | 0,3 | |
157.114 | 10 | 3,1 | 3,1 | 0,07 | 0,09 | 50 | 0,3 |
Code | 157.064 | |
Catheter (PUR) | Length cm | 6 |
Distal | 4,4 | |
Flowrate ml/min | Proximal | 4,4 |
Distal | 0,09 | |
Dead volume ml | Proximal | 0,09 |
I-0.9 cm | 50 | |
Straight guide | OMM | 0,3 |
Code | 157.114 | |
Catheter | Length cm | 10 |
Distal | 3,1 | |
Flowrate ml/min | Proximal | 3,1 |
Distal | 0,07 | |
Dead volume ml | Proximal | 0,09 |
I-0.9 cm | 50 | |
Straight guide | OMM | 0,3 |
Código tres vías:
1231.123
Triple-Lumen radiopaque BIO-STABLE thermosensitive polyurethane catheter, 4.5 Fr, length 12.5 cm, with soft fixation wings and two extensions marked “Proximal”, “Medium” and “Distal” for infusions, proximal line internal lumen 20 G, medium 23 G, distal line 23 G with introducer needle 21 G, length 40 mm and 5 ml syringe, a straight metal guidewire length 40 cm and diameter 0.46 mm with a dilator.
Umbilical catheters
"Umbilical Catheter (P.U.R. –XRO)"
Code:
1270.03 (3.5fr)
Code:
1270.05 (5.0fr)
P.U.R., ORX and transparent catheter, via vein or artery, supplied with a 2-way valve.
* Centimeter marking 4 to 25 cm from the distal tip.
* Hemocompatibility of P.U.R. (Thrombogenic risk reduction)
* It allows a longer implantation duration than a P.V.C catheter
"Umbilical Catheter (P.V.C. –XRO)"
Code:
270.03 (3fr)
Basic list:
060.167.6638
Code:
270.05 (5fr)
Basic list:
060.167.6646
P.V.C., ORX and transparent catheter, via vein or artery, for pressure measurements, perfusions, drug administrations, blood sampling, exchange transfusion. Marks every inch from 5 to 25 cm.
* Flexible and thermosensitive material with open and blunt distal tip to reduce vascular trauma.
"Polyurethane Double Lumen Umbilical Catheter 4 FR"
Code:
1272.14 (4fr)
* Distance from the distal tip printed numerically from 4 to 20 cm.
* Catheter length 20 cm
Length of the tips: 5 cm
* Completely radiopaque tube
* Lumen size: 2 x 20 G.
* It allows reducing the number of peripheral lines needed, preserving the venous capital of the newborn.
Neonatal Hypothermia: A global issue
Hypothermia is an important factor in neonatal morbidity and mortality, of all weights and gestational age, and especially for vulnerable premature babies.(1)
The incidence of hypothermia upon admission to the NICU in the delivery room is (2)
>= 56% for babys <750g>= 25% for babys <= 2500g
Environmental factors
Code: 37.09.14 – 37.09.15 – 37.09.16
Neohelp™ Neonatal suit to prevent heat loss.
Description: Neohelp sterile polyethylene neonatal occlusive suit to prevent heat loss, with double layer for greenhouse effect. Transparent, quiet and soft material, with a hood perfectly adjustable to the head of the newborn, with a pre-formed foam for position stabilization to keep the airways open, with central opening providing a tight seal that ensures heat maintenance, with a design that facilitates the placement of surveillance equipment, IV catheters and umbilical access.
Code | which neohelp? | |
37.09.14 | Small size 1 Kg, L 38cm x W 30 cm, Maternity – Level III | |
37.09.15 | Medium size 1 Kg to 2.5 Kg, L 44cm x W 38 cm, Maternity – Level I and II | |
37.09.16 | Large size, greater than 2.5 kg, L 50cm x W 38 cm, Maternity – Level I & II Emergency |
References
1. The Cochrane collaboration interventions to prevent hypothermia at birth in preterrm and/or low birthweight infants (review) 2010. 2. Dr Bhatt R. White and Trasitional hypothermia in preterm newborns journal of perinatology (2007). 3. World health organization (WHO) Thermal protection of the newborn: a practical guide 1997.Product description
Neohelp is a pouch that prevents hypothermia in newborns.
References
4. W.WMV. Mori R. Interventions to prevent hypothermia at birth in preterm and/or low birth weight infant RHL.Joly Pleural Drainage - 15 cm
Codes:
6635.12
635.14
635.18
Trocar thoracic PVC drain with X.R.O. with 2 side holes and with fixing disc.
Neonatal pleural drainage
Code:
625.080 (8fr)
625.100 (10fr)
Probe for neonatal drainage length 8 cm, with trocar integrated, Luer Lock female connector, marks every cm, with a side eye. 8 Fr and 10 Fr.
Thoracic trocar drain - 28 cm
Codes:
636.14
636.18
Thoracic PVC trocar drain with X.R.O line with 2 side holes and with fixing disc.
Thoracic trocar drainage
Codes:
626.12
626.16
Transparent PVC drain with X.R.O. - line with 2 side holes, the handle ensures a good grip and controlled introduction.
Controlled suction probe
PVC transparent tube, proximal fitting with side hole for digital control, (with plug incorporated) 4-5-6-7-8-10-12-16 Fr.
Code | Fr | Length |
535.04 | 4 | 29cm |
535.05 | 5 | 29cm |
535.06 | 6 | 29cm |
535.07 | 7 | 29cm |
535.08 | 8 | 29cm |
535.10 | 10 | 29cm |
Insertion kit for 1FR or 2FR Central Venous Catheter
with Modified Seldinger Technique.
Code: 1147.02
Kit contains: - A 24 G needle with a 15 "bevel angle, length 19 mm. - A symmetrical nitinol guidewire, 20 cm (Flexible tips and rounded heads on both sides; marked in 4.5 cm which indicates the protrusion of the guidewire beyond the needle bevel). - 2 FR, peelable / dilated guidewire, 18 mm in length.
Neo Safe
Code: 214.06 – 214.07
Needle for drip blood sample, with suitable bevel to avoid patient trauma and avoid risk of subcutaneous migration with the split needle.
It promotes an aseptic technique.
Easy to identify with the wing, reducing the risk of losing sight of the split needle.
Code | Gauge | Ø Ext. (mm) | Long. mm |
214.06 | 23 | 0.6 | 17 |
214.07 | 22 | 0.7 | 22 |
Neo Safe
Code: 214.06 – 214.07
Needle for drip blood sample, with suitable bevel to avoid patient trauma and avoid risk of subcutaneous migration with the split needle. It promotes an aseptic technique. Easy to identify with the wing, reducing the risk of losing sight of the split needle.
Codes | Gauge | Ø Ext. (mm) | Long. mm |
214.06 | 23 | 0.6 | 17 |
214.07 | 22 | 0.7 | 22 |
Endotracheal tube with secondary lumen for surfactant
Secondary lumen for tracheal irrigation (to provide surfactant and / or some other medication) or pressure monitors.
Tube | Secondary lumen | ||||
Code | 0 Int.mm | 0 Ext. mm | Long. mm | mm | Flow (ml/min) |
5516.20 | 2.0 | 3.4 | 165 | 0.40 | 2.15 |
5516.25 | 2.5 | 4.1 | 165 | 0.55 | 3.35 |
5516.30 | 3.0 | 4.6 | 165 | 0.65 | 5.00 |
5516.35 | 3.5 | 5.2 | 165 | 0.80 | 15.00 |
5516.40 | 4.0 | 5.7 | 230 | 0.95 | 35.00 |
Tube | Code | 5516.20 |
0 Int.mm | 2.0 | |
0 Ext. mm | 3.4 | |
Secondary lumen | Long. mm | 165 |
mm | 0.40 | |
Flow (ml/min) | 2.15 |
Tube | Code | 5516.25 |
0 Int.mm | 2.5 | |
0 Ext. mm | 4.1 | |
Secondary lumen | Long. mm | 165 |
mm | 0.55 | |
Flow (ml/min) | 3.35 |
Tube | Code | 5516.30 |
0 Int.mm | 3.0 | |
0 Ext. mm | 4.6 | |
Secondary lumen | Long. mm | 165 |
mm | 0.65 | |
Flow (ml/min) | 5.00 |
Tube | Code | 5516.35 |
0 Int.mm | 3.5 | |
0 Ext. mm | 5.2 | |
Secondary lumen | Long. mm | 165 |
mm | 0.80 | |
Flow (ml/min) | 15.0 |
Tube | Code | 5516.40 |
0 Int.mm | 4.0 | |
0 Ext. mm | 5.7 | |
Secondary lumen | Long. mm | 230 |
mm | 0.95 | |
Flow (ml/min) | 35.0 |
Mucus suction pump
Code: 534.10
Mucus suction device with an airtight container for subsequent laboratory culture.
A 10 FR probe is pre-assembled and a 6 FR probe allows aspiration for premature infants or low weight infants.
The container is provided with a cap allowing its tight seal by pressure after aspiration.
Copyright © All rights reserved, HUMANA DE EQUIPO Y MATERIALES, S.A. DE C.V.